TOYOPUC PC3JL-CPU

A library function, PC / CMP-LINK:2 port standard, and 7 segment display machine are added for the function/form of PC3J-CPU as it is.
Furthermore, it contributes to lead time shortening of the work from circuitry to preservation.

TOYOPUC PC3JL-CPU

1. The feature

  1. 1.TOYOPUC PC3J-CPU and Equivalent Function

    Three independent program execution, Loading of an equipment information memory, high-speed processing, A flexible user memory

  2. 2.Library function

    The load reduction of the sequence design and the number of sheets of the circuit drawing can be reduced by the library function. (Applicable only the PC3J mode.)

  3. 3.Event Monitor Ability

    ON/OFF of an alarm coil is detected by the sampling function,and an alarm code is extracted corresponding to it.
    A detailed,alarm display is supported by combining this function with the operation board. (Applicable only the PC3J mode.)

  4. 4.Communication-2-Port-Build as Standard.

    Two ports of PC /CMP links are built in as standard. A space-saving is realized.

  5. 5.The state display by 7 segment display machine

    7 segment display machine is built in. The RUN/ERR/ALM state of CPU can check at a glance.

2. General specification

Items Specification
Power supply AC85-264V 47 - 66 Hz (in the case of POWER1) DC 18-32V (in the case of POWER2)
Power consumption Less than [ 38W ] (80 or less VA) (in the case of POWER1) 40 or less VA (in the case of POWER2)
Ambient temperature 0-55℃
Relative humidity 30 - 85%RH (But no condensation allowed.)
Atmosphere No corrosive gas allowed.
Vibration resistance Conforming to JIS C0911. Frequency Acceleration Amplitude Sweep cycles
10~57Hz - 0.15mm 10 cycles
(1 octave /minute)
57~150Hz 9.8m/s2 -
Shock resistance Conforming to JIS C0912.(147m/s2 3 directions, 3 shocks in each direction)
Noise resistance nature 1000V It is based on a P.P (1 microsecond of noise width) noise simulator.
Insulation resistance For [ AC1500V ] 1 minute (during an AC external terminal-ground) For [ AC1000V ] 1 minute (during a DC external terminal-ground) 5V and OV It removes between terminals
Instant electric power failure The instantaneous blackout permission time 0.5 or less cycles 1s or more (in the case of POWER1) of the instantaneous blackout intervals the instantaneous blackout permission time 10 or less ms 1s or more (in the case of POWER2) of the instantaneous blackout intervals
Consumption current 390mA(Typ.)
Outside size 35(W)×130(H)×110(D)mm
Mass 0.22kg

3. Performance specification

Items The PC3J mode (initial cofiguration) PC2 compatible mode
Total Detail
Program system Stored program method
Program control method Cyclic operation method (subroutine function) Max. 3 programs Cyclic operation method(subroutine function)
Command kind Basic Command: 19 sort, Timer counter command:21 sort, application command: 450 or more sorts
Basic command processing speed 0.08 to 0.28 us/command (Contact), 0.12 to 0.48us /command (Output)
Application command processing speed 0.60us (min.)/word
Program capacity Sequence 48KW *1 16KW×3 32KW
User library 32KW(256)*2
I/O mark 1024 points 1024 points
Internal relay 14336 points *1 2048×3+8192 points 2048 points
Keeping relay 6400 points *1 768×3+4098 points 768 points
Timer counter 3584 points *1 512×3+2048 points 512 points
Link relay 14336 points *1 2048×3+8192 points 2048 points
Data register 12KW *1 4KW×3 12KW
Link register 6KW *1 2KW×3 2KW
Built-in communication port 2 link standard equipment
- Link 1 :PC / CMP-LINK (built-in standard link) *3 *4
- Link 2 :PC / CMP-LINK (built-in option link)
The number of the maximum link mounting 15 8
Equipment information memory 448KB 448KB *5
  • *1:Change by selection of allotment of a user memory.
  • *2:Only the PC3J mode corresponds.
  • *3:In use, 4 line type communication is possible only for a port 1.
  • *4:In an initial setup (he has no link parameter), operate as a computer link of standard specification.
  • *5:It is necessary to use Hellowin.