TOYODA

Upgrade information

PCwin-Safe2 (JPN/ENG) V2.2R08、 (FRA/CHN)V2.0R04

Release Date:October,2024

Upgrade Program's

[PCwin-Safe2 V2.2R08]
TJA-2071(JPN)
TJA-2073(ENG)
[PCwin-Safe2 V2.0R04]
TJA-6287(FRA)
TJA-6314(CHN)

Upgrade information

***** PCwin-Safe2 *****
Upgrade from V2.2R07 to V2.2R08
- Upgrade "PCwin- Safe-Nano" from V1.5R01 to V1.5R02
[Specification Change]
- Change the default setting of error category of I/O parameter from "Alarm" to "Minor Error" in "Convert Program" function.
[Bug Modification]
- Modify the problem that application terminates unexpectedly in "Convert Program" function.
- Modify the problem that PCwin-Safe-Nano terminates unexpectedly importing the ladder program generated by "Safety PLC CAD I/F" function.
***** PCwin-Safe-Nano *****
Upgrade from V1.5R01 to V1.5R02
[Function improvement]
- Change that the selected CPU operation mode is displayed on the "Select CPU Mode" window when creating the new project.
- Support the function that it displays the comment of selected symbol on the status bar.
- Change that FB version collation is also executed when project is saved and program size check is executed.
- Change that it can save the project changes by pressing "X" button of PCwin-Safe-Nano.
[Operability improvement]
- Support the function that save and reproduce the previous display position in "Edit Comment" and "Register+I/O Address Monitor".
- Change the default display position as follows in "Edit Comment" and "Register+I/O Address Monitor".
- Change that ladder window is not closed when saving project.
- Change that the text in the address field is all selected when the property window is opened to edit coil in the ladder window.
[Maintenability improvement]
- Modify the error message displayed in case of using the addresses from T/C000 to T/C00F in ladder circuit when using FB.
- Modify the SCID update request message displayed when changing the connection setting for CIP Safety.
- Modify the error message displayed when FB block is placed before the START instruction.
- Modify to display link address and link size on the CIP Safety connection setting screen in "Remote IO mode" and "PCS compatible mode(RMT)"
[Specification Change]
- Change the default setting of error category in I/O parameter setting from "Alarm" to "Minor Error".
[Bug modification]
- Modify the problem that it cannot be apply the setting change if the setting of "Wiring Method" is changed from "Single" to "Double".
- Modify the problem that PCwin-Safe-Nano terminates unexpectedly when it imports the ladder program generated by generated by "Safety PLC CAD I/F" function of PCwin-Safe2.
- Modify the problem that some FBs is imported empty when importing FB for PCS.
- Modify the problem that PCwin-Safe-Nano terminated unexpectedly when saving the project that caused program time over.
- Modify the problem that the tag of selected symbol cannot be displayed at "Tag Diaglam" field in "Search" window.
- Modify the problem that "Change" button is cannot be pressed in I/O parameter setting.
There is no upgrading of PCwin-Safe, PCwin-Safe-J and PCwin-Safe-Plus.
The versions of each programming tool are as follows:
- PCwin-Safe2 : V2.2R08
- PCwin-Safe : V3.2R01
- PCwin-Safe-J : V1.6R02
- PCwin-Safe-Plus : V1.3R03
- PCwin-Safe-Nano : V1.5R02